CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
3-30
990-412
The
WE2STOP
signal shuts off current immediately when input during the
WE2
period,
switching the sequence to
COOL2
. The
WE2STOP
signal shuts off current immediately after
the
WE2
starts (the current is supplied for about 1 cycle) when input before the
WE2
period,
switching the sequence to
COOL2
. The
WE2STOP
signal will not shut off current if input
during the
WE3
period.
The
WE3STOP
signal shuts off current immediately when input during the
WE3
period,
switching the sequence to
HOLD
. The
WE3STOP
signal shuts off current immediately after
the
WE3
starts (the current is supplied for about 1 cycle) when input before the
WE3
period,
switching the sequence to
HOLD
.
When the welding stop signal is input before the start signal is received, the welding stop error
occurs.
When
WELD STOP OFF TIME
is set, the current is supplied for the time period in
WE1/2/3
.
This weld time is the
WELD
repetition time except for the
INT
time.
EXAMPLE:
When
WELD STOP OFF TIME: 60ms
,
WELD: 15ms
,
INT: 10ms
, and repetition:
3
, the total time is 75ms. The welding current is supplied for at least 60ms and neglected for
15ms (
WELD: 5ms
+
INT: 10ms
).
This is also effective when the off time (
OFF
) is set. A welding is stopped when the signal is
input before each
WE
. A welding is performed when the signal is released before each
WE
.
g. WELD2 STOP/WELD COUNT
Set external input to pin 14. When
WELD2 STOP
is selected the weld count will not be checked.
The sequence will proceed to
COOL2
if external input pin 14 is closed during the
WELD2
sequence operation. When the
WELD2 STOP
signal is input before the start signal is input even
if the
WELD1
is set, the welding stop error occurs. When
WELD COUNT
is selected the weld
count will be checked.
h. WELD3 STOP/COUNT RESET
Set external input to pin 25. When
WELD3 STOP
is selected the count will not be reset. The
sequence will proceed to
HOLD
if external input pin 25 is closed during the
WELD3
sequence
operation. When the
WELD3 STOP
signal is input before the start signal is input even if the
WELD1
or the
WELD2
is set, the welding stop error occurs. When
COUNT RESET
is selected
the count will be reset.
i. FLOW SWITCH / PRG PROTECT
Set external input pin 21.
When
FLOW SWITCH
is selected
Flow switch input pin. Opening this pin will result in a flow rate error.
When
PRG PROTECT
is selected
Program inhibit input pin. Closing this pin will not allow you to change the settings.