![Amada S-2200CA Operation Manual Download Page 26](http://html1.mh-extra.com/html/amada/s-2200ca/s-2200ca_operation-manual_2915805026.webp)
CHAPTER 1: SYSTEM DESCRIPTION
IS-2200CA/4500CA INVERTER POWER SUPPLY
1-6
990-412
CHARGE INDICATOR Lamp
DANGER
Lethal voltages are present when the capacitors are charged. Do
not
touch the interior
of the Power Supply when the LED is ON.
Leave it alone for at least 20 minutes
after turning the Power Supply OFF.
DO NOT REMOVE SHIELD WITH POWER ON OR OPERATE THE
MACHINE WITH SHIELD REMOVED! THIS WILL RESULT IN DEATH.
This lamp is located on the panel next to the transformer
INPUT/OUTPUT
terminals on the Power Module.
The charge level of this electrolytic capacitor is indicated by the brightness of the
CHARGE INDICATOR
lamp. The more the capacitor is charged, the brighter the
CHARGE INDICATOR
lamp will be.
CHARGE INDICATOR
Summary of Contents for S-2200CA