APPENDIX E: COMMUNICATIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
E-17
Item
Contents
Character
String
Range
56
OUTPUT5
n,
5:GOOD
6:COUNTUP
7:OUTI
8:OUTII
57
DISPL SENSOR STEP
n.n
0.5 to 5.0(um)
*1 Items inhibited from setting (When setting data, omit these items.)
“,” is not transmitted, too.
Screen 07 (Error data) Common data (Schedule No.: 000)
•
Error data confirmation (Data reading only)
Item
Contents
Character
String
Range
1
Error code 1
nnn,
E01 to E39
2
Error code 2
nn,
01 to 39
3
Error code 3
nn,
01 to 39
4
Error code 4
nn,
01 to 39
5
Error code 5
nn,
01 to 39
6
Error code 6
nn,
01 to 39
7
Error code 7
nn,
01 to 39
8
Error code 8
nn
01 to 39
The number of error codes is of eight max. In the case of only one error code, the items 2 to 8 are
omitted. For error codes,
see
Chapter 5: Maintenance, Section I: Troubleshooting
.
•
Error reset (Data setting only)
Item
Contents
Character
String
Range
1
Error reset
nnn
E00
Screen 08 FORCE SETUP screen Specific data in accordance with Schedule No. (001 to 255)
Example of data writing:
#01W001S08:1,02000,02100,02200,02300,02400,02500,1,0,0,00000,0[CR][LF]
Item
Contents
Character
String
Range
1*
1
STEP MODE
n,
0:OFF 1:ON
2
PROPVALVE#
n,
1 to 2
3
SQD FORCE
nnnnn,
00000 to 35000(N)
00000 to 03569(kgf)
00000 to 07868(lbf)
4
SQZ FORCE
nnnnn,
5
WELD1 FORCE
nnnnn,
6
COOL1/WELD2 FORCE
nnnnn,
Summary of Contents for S-2200CA
Page 1: ...990 412 REV G INVERTER POWER SUPPLY IS 2200CA 4500CA OPERATION MANUAL...
Page 20: ......
Page 31: ...CHAPTER 1 SYSTEM DESCRIPTION IS 2200CA 4500CA INVERTER POWER SUPPLY 990 412 1 11...
Page 38: ......
Page 114: ......
Page 136: ......
Page 168: ......