CHAPTER 2: INSTALLATION AND SETUP
IS-2200CA/4500CA INVERTER POWER SUPPLY
2-2
990-412
Power Requirements
Power required for the Power Supply is three-phase, 380 or 480 VAC (nominal), 50-60 Hz. When
changing the input voltage, the valve transformer input leads will need to be changed to the new voltage.
NOTES:
•
All items other than IS-2200CA/4500CA are sold separately.
•
In the secondary constant-current effective value control and secondary constant-power effective
value control, a toroidal coil and a volt-sensing cable are required. Connect the volt-sensing
cable near an electrode and connect the opposite side of the cable to pins TB5-1 and TB5-2 on
the external I/O terminal strip.
NOTE:
If used with AMADA WELD TECH IT Transformers, you can purchase the 18-045-01
transformer sense cable which will have these connections.