CHAPTER 5: MAINTENANCE
IS-2200CA/4500CA INVERTER POWER SUPPLY
5-8
990-412
IS-4500CA Service Safety Precautions
DANGER
DEATH ON CONTACT
may result if you fail to observe all safety precautions.
Lethal voltages
are present in the Power Supply. Perform the following steps to
eliminate electrical shock hazard. Make sure external power is turned OFF before
performing any maintenance procedures.
1.
Turn the power to the IS-4500CA Power
Supply OFF by pressing the OFF button
on the circuit breaker located on the right
side of the IS-4500CA.
2.
Open the front door.
3.
The capacitors will automatically
discharge in about 30 seconds. If the
Charge Indicator is lit (see illustration to
the right), then the IS-4500CA contains
lethal voltages. DO NOT service until
the lamp is off and at least 30 seconds of
time have lapsed.
NOTE:
If necessary for maintenance, remove the Safety Shields by removing the four
securing screws. The Safety Shield (below) is highlighted for clarity.