CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-49
15. PROGRAM PROTECT MODE Screen
When this function is used, set values cannot be changed by any person other than the supervisor.
PROGRAM PROTECT
is usually set to OFF. When it is set to ON, set values cannot be changed
until
PROGRAM PROTECT
is set to OFF again.
Follow the procedure below to change the setting of
PROGRAM PROTECT
.
1.
Turn the power supply ON using the
key pressed or connect the MA-660A to the circuit cable
with the power supply turned ON. The following screen is displayed:
2.
When the
ENTER
key is pressed after the
+ON
key is pressed,
ON
is displayed.
You cannot go to other screens from this screen. Also, the external signals cannot be received.
3.
Turn off the power supply and turn on it again, or disconnect the MA-660A with the power
supply turned on and connect to the circuit cable again. When
PROGRAM PROTECT
is ON,
the display of the
MENU
screen changes.
COPY SETUP DATA, I/O CHECK
and
RESET TO
DEFAULT
are not displayed. On the other screens, the cursor can be moved and the settings
can be checked, but the settings cannot be changed.
<When the PROGRAM PROTECT is OFF>