CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
3-16
990-412
k. CAP CHANGE
The number of times before prior notice for cap change setting for the stepper used for the
displayed SCHEDULE is displayed when STEPPERMODE is not OFF on the MODE SELECT
screen. The latest measured value welded with the displayed SCHEDULE No. is displayed.
l. TOTAL COUNTER
The display changes depending on the setting of WELD2 STOP/WELD COUNT and
COUNTER on the MODE SELECT screen.
1.
When
WELD2 STOP/WELD COUNT
is
WELD2 STOP
and
COUNTER
is
TOTAL
TOTAL COUNTER is displayed. The count value is incremented by one despite the result
of the upper/lower limit judgment in monitoring.
2.
When
WELD2 STOP/WELD COUNT
is
WELD2 STOP
and
COUNTER
is
GOOD
.
GOOD COUNTER
is displayed. The count value is incremented by one when the monitored
value is within the range of the upper/lower limit.