APPENDIX A. TECHNICAL SPECIFICATIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
A-4
990-412
Parameter
IS-2200CA
IS-4500CA
Error
conditions
No-current
Power is turned off in the following cases:
a. When a secondary current is not detected in Secondary constant-
current effective value control, Secondary constant-power effective
value control, or Constant-phase control.
b. When a primary
No-voltage
Under Secondary constant-voltage effective value control or Secondary
constant-power effective value control, the supply of current is stopped
when a secondary voltage cannot be detected.
Temperature
Overheating of power unit of inverter and welding transformer are
detected.
Self-diagnostic error
Setting dates (e.g., schedule settings) are diagnosed.
CURRENT
Calibration
Adjustment
Percentage of setting
-24 to +24
*: selectable for all 255 schedules
NOTES:
1.
No repetitive operation will be performed if “0” is selected for OFF (off time).
2.
Primary current can be set up to 2200A for
IS-2200CA
and 4500A for
IS-4500CA
.
3.
Using the fixed load and the specified transformer
−
The weld time is 100ms. The measurement range is from 60ms to 100ms.
−
The voltage may be out of the range due to the induced electromotive force.
Accessories (optional)
Option
Model No.
Length
Pendant Cable
18-047-01-02
2 ft
18-047-01-05
5 ft
18-047-01-10
10 ft
18-047-01-15
15 ft
18-047-01-20
20 ft
18-047-01-33
33 ft
18-047-01-50
50 ft
18-047-01-66
66 ft
Secondary Sensing
Toroidal coil
MB-400L (Belt, 1.54 ft approx.)
Cable, 9.2 ft
MB-800L (Belt, 2.92 ft approx.)