CHAPTER 5: MAINTENANCE
IS-2200CA/4500CA INVERTER POWER SUPPLY
5-2
990-412
FAULT
CODE
CONTENTS
CAUSE
MEASURES
E-09
OUT LIMIT OF
PULSE WIDTH
ERROR
Welding Current pulse width is out of
PULSE HI
setting range on
MONITOR
SET
screen.
Check that the transformer capacity is
sufficient.
Check workpiece and welding electrode.
E-10
SET ERROR
Primary current of turn ratio is out of range
of the following formula:
IS-2200CA
: X = 45, Y = 2200
IS-4500CA
: X = 90, Y = 4500
Correct each setting.
The
WELD1
,
WELD2
, and
WELD3
values are all “0.”
The total time of
UP SLOPE
and
DOWN
SLOPE
is longer than the
WELD
time.
HEAT
setting, including
RATIO
setting is
equal to or lower than UF or DL setting.
Although STEPPER MODE is set to
LINER or FIXED, STEPPER COUNT of
STEP number set for START ON STEP#
are all “0.”
The series of welding currents in WELDs
without COOL are different than the
consecutive UP/DOWN settings.
UP/DOWN is set in the consecutive portion
of a series of WELDs without COOL and
the portion meets specific conditions.
On ADVANCED Power Supply models
the transformer weld frequency was set
greater than 1000Hz
E-11
SET OVER
HEAT
setting (including
RATIO
setting)
is equal to or lower than UF or DL setting.
Correct each setting.
HEAT
setting (including
RATIO
setting)
is larger than the maximum current,
voltage, or power setting.
HEAT
setting (including
RATIO
setting)
is lower than the minimum value of current,
voltage, or power setting.
HEAT
setting
TURNS RATIO
X
≤
≤
Y