APPENDIX C: SYSTEM TIMING
IS-2200CA/4500CA INVERTER POWER SUPPLY
C-4
990-412
A: DELAY START SET s Welding preparation time
The welding preparation time changes depending on the WELD TRANS FREQ (frequency) setting.
Frequency [Hz] Welding preparation time [ms] Frequency [Hz] Welding preparation time [ms]
600
1.1
1000 to 1200
0.7
700
1.0
1300 to 1600
0.6
800
0.9
1700 to 2400
0.5
900
0.8
2500 to 3000
0.4
B: END SIGNAL TIME setting
The output time changes depending on the OFF time. See
Chapter 3: Using Programming Functions, Section 10:
Mode Select Screen, Sub-section c: End Signal Mode
.
C: Monitored value judgment time
200μs
max.
(Note 1)
To stop the sequence during
SQD
or
SQZ
(possible only when LATCHED or MAINTAINED is
selected for
START SIG. MODE
; see
Chapter 3: Using Programming Functions, Section 10: Mode
Select Screen, Sub-section b: Start Signal Mode
, stop the 2ND STAGE input for a period longer than
that set for
DELAYSTART SET
.
(Note 2)
When the current gets out of the range of upper/lower limit judgment (ERROR) in a sequence,
repetition operation ends even if the OFF time is set.