CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-27
2)
OFF
time is set (10ms ≤ OFF time)
a)
END SIG.TIME
time is shorter than
OFF
time (
END SIG.TIME
time <
OFF
time)
End signal time is the set
END SIG.TIME
time. (
END
time =
END SIG.TIME
time).
b)
OFF time is longer than
END SIG.TIME
time (
END SIG.TIME
time ≥
OFF
time)
End signal time is the
OFF
time. (
END
time =
OFF
time)
d. END SIGNAL MODE
Set the conditions for output of the end signal upon completion of the weld sequence.
0.
Outputs the end signal even when the monitored value is outside the upper and lower
tolerance limits. The end signal will not be output in the event of an error or when the
sequence is interrupted by
START SIGNAL MODE (MAINTAINED).
1.
The end signal will not be output when the monitored value is outside the upper and lower
tolerance limits (
*
), in the event of an error, or when the sequence is interrupted by
START
SIG.MODE (MAINTAINED)
.
2.
The end signal will be output even when the monitored value is outside the upper and lower
tolerance limits (*), even in the event of an error, and even when the sequence is interrupted
by
START SIGMODE (MAINTAINED).
NOTE
: There is no distinction between
ERROR
and
CAUTION
.
END signal output
END SIG.
MODE
NORMAL
COUNT-
RELATED
ERROR
UPPER/LOWER
LIMIT ERROR
OTHER
ERRORS AT
WELDING
STOPPED HALFWAY
(MAINTAINED)
0
Output
Output
Output
No output
No output
1
Output
Output
No output
No output
No output
2
Output
Output
Output
Output
Output
NOTE:
For faults, see the Fault Code List. Priority is “Stopped halfway” = “Other errors at
welding” > “Upper/lower limit error” > “Count-related error”.
e. WELD TIME
Use this setting to change the units for time settings available on the
SCHEDULE screen
.
CYC
50Hz: 1CYC = 20ms
60Hz: 1CYC = 16.6ms
ms
—