
CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-19
f. PULSE
If the ratio of welding current pulse / pulse width in full wave mode exceeds the percentage set
in the
PULSE HIGH
, an
ERROR
signal is output. Pulse width is expressed assuming that the
full wave is 100%.
NOTE:
Upper/Lower limit judgment value when
STEPPER MODE
is set to
ON
The upper/lower limit judgment value set here is for the current when a welding is performed,
not for the initial setting. Therefore, when
STEPPER MODE
is set to
ON
to perform step-up
(step-down) for the initial setting, the upper/lower limit judgment value is stepped up or down
automatically.
EXAMPLE:
When the current is set to 2 kA, HI; 2.2 kA, LO; 1.8 kA. When the step becomes
150%,
H
and
L
become as follows.
H: 2.2 x 1.5 = 3.3 kA
L: 1.8 x 1.5 = 2.7 kA
6. NG SIGNAL SELECT Screen
Sets the output mode and the signal for each item to output,
ERROR
or
CAUTION
, in an error
occurring.
NOTE:
This screen shows initial settings.
a. ERROR OUTPUT MODE
Sets the output modes of
NG1
of the external output signals.
N.C.
(NORMAL CLOSE) Closed at normal / Open at error
N.O.
(NORMAL OPEN) Open at normal / Closed at error
NOTE: NG2 is N.O. only
(a)
(b)
Summary of Contents for S-2200CA
Page 1: ...990 412 REV G INVERTER POWER SUPPLY IS 2200CA 4500CA OPERATION MANUAL...
Page 20: ......
Page 31: ...CHAPTER 1 SYSTEM DESCRIPTION IS 2200CA 4500CA INVERTER POWER SUPPLY 990 412 1 11...
Page 38: ......
Page 114: ......
Page 136: ......
Page 168: ......