CHAPTER 5: MAINTENANCE
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
5-17
Section V: Repair Service, Storage, Shipment
Repair Service
If you have problems with your Control that you cannot resolve, please contact our service department at
the address, phone number, or e-mail address indicated in the Foreword of this manual.
Preparation for Storage or Shipment
1.
Disconnect power to the Power Supply then wait 20 minutes after power is removed before the
following procedures.
2.
Turn off water source and disconnect the water hoses to the Power Supply. Using shop air, dry
out the hoses.
3.
Remove the circuit breaker line terminal cover and disconnect all line wires. Replace cover.
4.
Disconnect all load wires.
5.
Disconnect all signal wires
6.
Remove any conduits from the top and bottom of the Power Supply as necessary.
7.
If a secondary current sensor is used, disconnect the signal cable from the connector on the
bottom of the Power Supply.
8.
Replace the plastic cover and secure it with the four mounting screws.
9.
Remove the Power Supply from its mounting location.
10.
Repack the Power Supply into the original packing materials and packing box in which you
originally received the Power Supply.