CHAPTER 2: INSTALLATION AND SETUP
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
2-13
5.
Drill appropriate hole(s) in the removable lower panels to receive the output power (weld
transformer) conduit(s).
NOTE:
Remove
all metal shards,
then re-install the plate.
6.
Install the weld transformer conduit to the plate and feed cables into the Power Supply.
7.
Connect the ground cable to the ground lug.
8.
Connect the two transformer cables to the power module.
9.
Replace the plastic high voltage protection panel and secure it in place with the screws
removed in Step 1.
Signal Sensing Connections
See
Appendix B, Electrical and Data Connections, Section I, Data Connectors
for connector pin
information
and
Section II, Input / Output Signal Configuration
for connection and configuration
instructions.