CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-55
17. DISPLACEMENT Screen
This screen is used to make a measurement using a displacement gauge and set the weld stop
function.
a. SCHEDULE #
Select from #001 to #255 to set the
SCHEDULE
.
Normally select #001 first, then select additional schedules in sequential order.
b. WELD STOP INPUT
Select items for weld stop.
OFF
: External Input,
WE1
to
WE3
Stop Input are effective.
DISPLC
:
Weld Stop works at the set displacement value.
CURR
: Weld Stop works at the set current value.
VOLT
: Weld Stop works at the set voltage value.
POWER
: Weld Stop works at the set power value.
PULSE
:
Weld Stop works at the set pulse width.
c. WELD STOP CONDITION
Set values for items selected in
WELD STOP INPUT
.
OFF
: Not displayed.
DISPLC
:
Set the value of displacement.
CURR
: Set current value.
VOLT
: Set voltage value.
POWER
: Set power value.
PULSE
:
Set pulse width.
d. WORK DETECT LIMIT
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)