![Amada S-2200CA Operation Manual Download Page 182](http://html1.mh-extra.com/html/amada/s-2200ca/s-2200ca_operation-manual_2915805182.webp)
APPENDIX C: SYSTEM TIMING
IS-2200CA/4500CA INVERTER POWER SUPPLY
C-14
990-412
b: Weld1 stop (WE1)
When the displacement weld stop (DISPLC) is set to the weld1 stop
on the DISPLACEMENT screen and the displacement sensor arrives
at the set displacement (f at the above figure), the weld1 stop is
stopped to make the sequence move to the next cool time(CO1).
c: Weld2 stop (WE2)
When the displacement weld stop (DISPLC) is set to the weld2 stop
on the DISPLACEMENT screen and the displacement sensor arrives
at the set displacement(g at the above figure), the weld2 stop is
stopped to make the sequence move to the next cool time(CO2).
d: Weld3 stop (WE3)
When the displacement weld stop (DISPLC) is set to the weld3 stop
on the DISPLACEMENT screen and the displacement sensor arrives
at the set displacement(h at the above figure), the weld3 stop is
stopped to make the sequence move to HOLD.
e: Delay time
When the delay time is set on the DISPLACEMENT screen, the
displacement (i at the above figure)after the delay time elapses is
measured.
(Notes)
•
The displacement of work detection is set as 0mm (reference point) at “j” (right before
SQD).
•
“k” at the end of work detection is set as 0mm (reference point) of weld stop and the
final displacement (0mm for work detection and 0mm for the final displacement monitor
are different.)
•
The displacement between “k” and “j” is the monitor displacement (WORK DETECT
MONITOR) for work detection.
•
The displacement between “j” and “i” is the monitored value of the final displacement
(DISPLACEMENT MONITOR).
Summary of Contents for S-2200CA
Page 1: ...990 412 REV G INVERTER POWER SUPPLY IS 2200CA 4500CA OPERATION MANUAL...
Page 20: ......
Page 31: ...CHAPTER 1 SYSTEM DESCRIPTION IS 2200CA 4500CA INVERTER POWER SUPPLY 990 412 1 11...
Page 38: ......
Page 114: ......
Page 136: ......
Page 168: ......