APPENDIX B. ELECTRICAL AND DATA CONNECTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
B-11
PIN
NAME
DESCRIPTION
TB3-3
TB3-4
ANALOG OUT1+
ANALOG OUT1-
0-10VDC Analog output 1*
2
TB3-5
TB3-6
ANALOG IN2+
ANALOG IN2-
0-10VDC Analog input 2
TB3-7
TB3-8
ANALOG OUT2+
ANALOG OUT2-
0-10VDC Analog output 2*
2
TB3-9
TB3-10
CURRENT OUT+
CURRENT OUT-
Current output (0-10 VDC)*
2
V
OUT
= I
OUT
/ 5000
TB3-11
TB3-12
VOLTAGE OUT+
VOLTAGE OUT-
Voltage output (0-10 VDC)*
2
V
OUT
= V
FEEDBACK
/ 2
TB3-13
TB3-14
EXT. COM
For internal Sink (pull down) Connect to pin 1. For Internal Source (push up)
Connect to pin 4.
To activate input in Sink Mode, connect inputs to INT +24VDC GND (I/O COM)
To activate input in Source Mode, connect inputs to INT +24VDC
For External Sink attach PLC +24V. For External Source, attach PLC COM
TB4-1
RETRACTION 1
Control pin for Retraction 1 Valve
TB4-2
INT +24VDC GND
(I/O COM)
COM pin. This pin is internally connected to the +24VDC GND
TB4-3
RETRACTION 2
Control pin for Retraction 2 Valve
TB4-4
BACK STEP
Input terminal for the back step. When the signal is input with
the successive function, the SCHEDULE No. returns to the
previous one. Also, when the signal is input over 1.5
seconds, the SCHEDULE No. returns to the first one.
TB4-5
STEP MODE
Input terminal. Each time closed on the FORCE SETUP &
MONITOR screen, the sequence proceeds to the next step.
TB4-6
INT +24VDC OUT
NOTE:
Do not use pin 1 unless connecting it to pin 2 or 3. Failure to observe this
precaution will result in malfunction.
MAX CURRENT DRAW:
100mA
TB4-7
CONTACTORS
Switch closure between Pin 40 and Pin 41 will engage the optional contactor
TB4-8
CONTACTOR N.O.
Detect position of contactors between pin 42 and 43: contactors normally open
(optional)
TB4-9
CONTACTOR
COM
Contactor Aux contact common (optional)
TB4-10
CONTACTOR N.C.
Detect position of contactors between pin 44 and 43: contactors normally closed
(optional)
TB4-11
NO CONNECTION
TB4-12
INT +24VDC GND
I/O COM pin. This pin is internally connected to the +24VDC GND
Summary of Contents for S-2200CA
Page 1: ...990 412 REV G INVERTER POWER SUPPLY IS 2200CA 4500CA OPERATION MANUAL...
Page 20: ......
Page 31: ...CHAPTER 1 SYSTEM DESCRIPTION IS 2200CA 4500CA INVERTER POWER SUPPLY 990 412 1 11...
Page 38: ......
Page 114: ......
Page 136: ......
Page 168: ......