CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-53
i. HOLD
Set the force of the electro pneumatic proportional valve (ANALOG OUT) output during
HOLD.
j. VALVE #
Two or four valves (welding heads) can be connected to the Power Supply. Use this setting to
select which of the two valves to use.
Operation differs according to the VALVE MODE setting on the MODE SELECT screen.
When VALVE MODE is 1 VALVE
Set the valve # in the range of 1 to 4.
EX SOL1 to EX SOL4 on the I/O terminal block.
VALVE #1: EX SOL1
VALVE #3: EX SOL3
VALVE #2: EX SOL2
VALVE #4: EX SOL4
When VALVE MODE is 2 VALVE
Set the valve # in the range of 1 to 2.
SOL1 and SOL2, and EX SOL1 to EX SOL2 on the I/O terminal block are used for valve
output.
VALVE #1: SOL1, SOL2
VALVE #2: EX SOL1, EX SOL2
k. FORGE VALVE #
The forge force function can be used.
The forge valve can be used at the given timing (the head force can be changed) except the valve
selected in
VALVE #
.
Select a valve to output the forge force.
Operation differs according to the VALVE MODE setting on the MODE SELECT screen.
When VALVE MODE is 1 VALVE
The forge valve No. is set in the range of 1 to 4.
Do not set the same number as that used for the valve No.
EX SOL1 to EX SOL4 on the I/O terminal block are used for valve output.
FORGE VALVE #1: EX SOL1 FORGE VALVE #3: EX SOL3
FORGE VALVE #2: EX SOL2 FORGE VALVE #4: EX SOL4
When VALVE MODE is 2 VALVE
FORGE VALVE # is fixed to 4.
EX SOL4 on the I/O terminal block is used for valve output.
Valid only when FORGE MODE is ON.