APPENDIX E: COMMUNICATIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
E-2
990-412
Section II. External Communication Function
Introduction
The
IS-2200CA/4500CA
can be used to set schedules from an externally-connected personal computer
(abbreviated as PC) or to read monitored data and several kind of status data.
Data Transmission
ITEM
CONTENT
Transmission Mode
Select only one mode on the MODE SELECT screen:
RS-232C (RS-485 requires factory installed RS-485 option)
See
Chapter 3: Using Programming Functions, Section 10:
Mode Select Screen, Sub-section S: Comm Mode
Communication
Control
Select either “one-way” (RS-232) or “Both-way” (RS-485)
communication.
Transmission Rate
Select either of the followings at MODE SELECT screen:
9600, 19200, 38400 bps
See
Chapter 3: Using Programming Functions, Section 10:
Mode Select Screen, Sub-section T: Comm Speed
Data Format
Start bit: 1, Data bit: 8, Stop bit: 1, Parity bit: Even
Character Code
ASCII
Checksum Data
None
Connector
D-Sub 9 pins
Pin Position
RS-232C, 2: RXD, 3: TXD, 5: SG, 7: RTS
(RS-485 requires factory installed RS-485 option)