CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-15
d. VOLTAGE
The voltage during which current was supplied in the course of
WELD1
,
WELD2
and
WELD3
operations are displayed. To display the voltage, you need to measure the secondary voltage by
connecting the voltage detecting cable. The latest measured value welded with the displayed
SCHEDULE
No. is displayed.
e. POWER
The power during which current was supplied in the course of
WELD1
,
WELD2
and
WELD3
operations are displayed. The value calculated from current and voltage (current x voltage) is
displayed. To display the voltage, you need to measure the secondary voltage by connecting the
voltage detecting cable. The latest measured value welded with the displayed
SCHEDULE
No.
is displayed.
f. PULSE
The widest pulse among the supplied primary pulse current is displayed as a percentage of pulse
width in full wave mode. The pulse width in full wave mode varies with the frequency setting
(
WELD TRANS FREQ
). The latest measured value welded with the displayed
SCHEDULE
No. is displayed.
NOTE:
The value displayed on the MONITOR screen is the average of value sampled at each
welding pulse. Therefore, the value may differ from the measurement value of a weld checker
(
MM-370B
etc.).
g. STEP #
The present number of steps is displayed when
STEPPER MODE
is not OFF on the MODE
SELECT screen.
h. STEPPER COUNT
The number of welds in the present step is displayed when
STEPPERMODE
is not OFF on the
MODE SELECT screen.
i. STEP2 REPEAT
Remaining number of repetition for the stepper used for STEP2 of the displayed SCHEDULE
is displayed when
STEPPERMODE
is not OFF on the MODE SELECT screen. The latest
measured value welded with the displayed
SCHEDULE
No. is displayed.
j. STEP RATIO
The step-up (-down) ratio is displayed when
STEPPERMODE
is not OFF on the MODE
SELECT screen. The latest measured value welded with the displayed
SCHEDULE
No. is
displayed.