CHAPTER 1: SYSTEM DESCRIPTION
IS-2200CA/4500CA INVERTER POWER SUPPLY
1-2
990-412
•
Seven protective functions for maximum ease of operation:
No-current / no-voltage
Over current
Temperature
Self diagnostics
Grounding error
Load short error
Phase error
•
Circuit breaker is included (IS-2200CA: 800 amps; IS-4500CA: 1200 amps).
•
120VAC valve voltage: 500VA
•
24VDC valve voltage: 5 amps (optional)
•
CE compliance optional.
•
RS-232 communications standard, RS-485 optional.
•
The analog output terminal (voltage output proportional to force) for electro-pneumatic proportional
valve and the analog input terminal (voltage input proportional to force) for force measurement have
two channels, respectively.
•
Welding can be stopped at the set displacement by connecting the displacement gauge and measuring
the displacement produced in fusing.