CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
3-50
990-412
When the PROGRAM PROTECT is ON>
16. FORCE SETUP & MONITOR Screen
This screen is used to set and monitor the force of the electro pneumatic proportional valve. Two
electro pneumatic proportional valves can be used. The ANALOG OUT output terminal (voltage
output proportional to force) for electro pneumatic proportional valve and the ANALOG IN input
terminal (voltage input proportional to force) for force measurement have two channels,
respectively. Also, chaining, successive and forge force functions can be set.
a. SCHEDULE #
Select from #001 to #255 to set the
SCHEDULE
.
Normally select #001 first, then select additional schedules in sequential order.
b. PROP VALVE #
Two electro pneumatic proportional valves can be connected.
Select an electro pneumatic proportional valve to use.
(b)
(j)
(k)
(l)
(m)
(a)
(c)
(n)
(o)