7-2 Function Code List
– System-Related Function
Code No.
Function Name
Data Content
Setting
Resolution
Factory
Presets
User
Setting
Value
System-Related Function
1601
Copy function
0: No function
1: Transfer the current code data to the operation
panel
2: Transfer the contents stored by operation panel to
the inverter (Excluding motor parameters measured)
3: Transfer the contents stored by operation panel to
the inverter (Including motor parameters measured)
1
0
1602
Changed code display function
0: No function
1: Display differences from factory preset
2: Display differences from user‘s initial value
1
0
1603
Function lock
0: Code data changeable (No lock function)
1: Code data unchangeable (except F1603)
2: Code data unchangeable
(except frequency setting-related)
(except F1603, F1021, F2101 - F2116)
3: Code data unchangeable (except F1603 and
function codes using communication)
1
0
1604
Data initialization
0: No function
1: Initialize factory presets
2: Invalid parameter by auto tuning
3: Initialize user‘s data
99: Set user‘s initial value
1
0
1605
Quick knob long-pressing cancel
selection
0: Long-pressing cancel disabled
1: Long-pressing cancel enabled
1
0
1606
Function code value setting key
selection
1: ―Set‖ key only
2: ―Quick knob‖ only
3: Both quick knob and Set key
1
1
1607
Target frequency setting time-out
0: Timeout disabled
1 - 60: Timeout (sec.)
1
5
1701
Output current limiting function
Mode A
0: No function
50-200%
1%
150
Mode B
0: No function
50-150%
120
1702
Electric thermal setting
0: No function
20-105%
1%
100
1703
Output current limiting at
constant speed
0: No function
1: Yes, V/F mode, (Currently selected
acceleration/deceleration time)
2: Yes, V/F mode, (1st acceleration/deceleration time)
3: Yes, V/F mode,
(2nd acceleration/deceleration time)
4: Yes, V/F mode,
(3rd acceleration/deceleration time)
5: Yes, V/F mode, (4th acceleration/deceleration time)
6: Yes, V/f mode and speed vector control mode
(1st acceleration/deceleration time)
7: Yes, V/f mode and speed vector control mode
(2nd acceleration/deceleration time)
8: Yes, V/f mode and speed vector control mode
(3rd acceleration/deceleration time)
9: Yes, V/f mode and speed vector control mode
(4th acceleration/deceleration time)
1
0
1704
Overload pre-alarm value
Mode A
20-200%
1%
150
Mode B
20-150%
120
1705
Motor type
1: General-purpose motor
2: Exclusive motor for the inverter
1
1
1706
Switching between ―OV‖ & ―LV‖
alarms when stopped
0: ―OV‖ enabled, ―LV‖ disabled when stopped
1: ―OV‖ disabled, ―LV‖ enabled when stopped
2: ―OV‖ disabled, ―LV‖ disabled when stopped
3: ―OV‖ enabled, ―LV‖ enabled when stopped
1
0
1707
Open Phase detection function
0: ―input open phase detection‖ disabled,
―output open phase detection‖ disabled
1: ―input open phase detection‖ enabled,
―output open phase detection‖ disabled
2: ―input open phase detection‖ disabled,
―output open phase detection‖ enabled
3. ―input open phase detection‖ enabled,
―output open phase detection‖ enabled
1
3
1708
Overvoltage stalling prevention
function
0: No overvoltage stalling prevention function.
1: Overvoltage stalling prevention function.
1
1