- 252 -
7-3
Description of Functions
Position function control
The followings are functions required for position control. An optional board (SC-PG) should be configured for the
position control of pulse command. Please refer to the instructions of optional board for details.
F8101
Point to point control position limiter
F8102
Point to Point control
effective number of digits(unit:mm)
F8107
Deviation counter clear mode
F8144
Number of pulses within 1 mm
F8115
Point to point control command
The function of point to point control is a function to run according to the number of pulses even when there is no pulse
command.
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F8101
Point to point control position
limiter
1-32767mm
1mm
32767
F8102
Point to Point control
effective number of digits(unit:mm)
1: Integer
2: 1 digit after decimal point is effective
3: 2 digits after decimal point is effective
1
1
F8107
Deviation counter clear mode
1: Level operation
2: Rising edge operation
1
2
F8114
Number of pulses within 1 mm
0: Number of pulse is specified with F8115
1-32767 pulse(s)
1 pulse
0
F8115
Point to point control command
0: No function
1-32767 pulse(s) (
※
1)
0.01-32767mm(
※
1)
1 pulse
0.01/0.1/1mm
(
※
1)
0
※
1: The data content and setting resolution of F8115 depend on the settings of F8114 and F8102, the following table
shows the variation.
F8114
F8102
F8115
Data content
F8115
Setting Resolution
0
Overall
0: No function
1-32767 pulse(s)
1 pulse
Beyond 0
1 (integer)
0: No function
1-32767mm
1mm
2 (1 digit after decimal point is effective)
0: No function
0.1-3276.7mm
0.1mm
3 (2 digits after decimal point is effective)
0: No function
0.01-327.67mm
0.01mm
The following is the setting sequence for point to point function.
Sequence 1: Setting of point to point control command (F8102, F8115)
Set the point to point control position command. The setting range is variable according to the combination
with F8102 (
Point to Point control
effective number of digits
).
・
When F8115=0: No point to point control function
・
When F8115 setting is not 0: the range will vary according to the values of F8114 and F8102. Please refer to
the above table.
※
During the setting of control command is not 0, please set the initialization value in F8115 when inputting
the deviation counter clearing signal (CCL). When inputting the deviation counter reverse clearing signal,
please set the initialization value in F8115 with a negative. Then the deviation counter connected to the
power supply will be cleared.
※
The deviation counter is a counter to count the deviations of command pulse and PG feedback pulse. When
inputting the command pulse, an optional board (SC-PG) must be configured additionally.