- 272 -
7-4
Serial Communication Function
⑬
Inverter operation and control terminal board input status data
Data read by from Operation Status 1 (H), Operation Status 2 (I) and Control Terminal Board Input Status (J)
commands are as follows:
①
Operation Status 1
Operation Status 1 data is returned in two bytes
First byte
JOG
0 0
0
0 0
JOG operation
Stage 1
0 0
0
0 1
Current number of stages in
multi-speed operation
Stage 2
0 0
0
1 0
Stage 3
0 0
0
1 1
Stage 4
0 0
1
0 0
Stage 5
0 0
1
0 1
Stage 6
0 0
1
1 0
Stage 7
0 0
1
1 1
Stage 8
0 1
0
0 0
Stage 9
0 1
0
0 1
Stage 10 0 1
0
1 0
Stage 11 0 1
0
1 1
Stage 12 0 1
1
0 0
Stage 13 0 1
1
0 1
Stage 14 0 1
1
1 0
Stage 15 0 1
1
1 1
Stage 16 1 0
0
0 0
bit 4 3 2 1 0