6-3 Special Functions
6-3-4 3 Wired Operation
Set F1101=4 and wire the circuit as shown in Figure 6-6, the inverter can operate run and stop by using a push
button.
Figure 6-6 Cricuit of 3wired operation
If STOP is ON and RUN is ON, then the inverter will start driving. If STOP is OFF, then the inverter will stop driving.
This operation is not same hold operation. Revolution direction of the motor can select FR/RR function. If FR/RR is
OFF, then revolution direction is forward. If FR/RR is ON, then revolution direction is reverse.
When F1104 set 4, the inverter can‘t operate by using FR terminal and RR terminal. User need to set each used
multifunctional input terminals RUN, STOP and FR/RR.
RUN
STOP
OFF:FR
ON:RR