4-5 Composition of Control Circuit Terminals
4-5-6
Communication Function Terminal
1)
RS485 communication
The communication control with peripheral devices can be realized by using RS485 communication terminal
block on the following main control board.
SW2 is a switch for turning ON / OFF the terminating resistor. Please set only the farthest terminating
resistor switch of the inverter to ON. (Factory preset= OFF: terminating resistor OPEN).
Inverter signal receiving end + signal
Inverter signal receiving end - signal
Inverter signal sending end + signal
Inverter signal sending end + signal
Note: Please refer to Description of Communication Functions for details of the communication functions.