- 281 -
-
281
-
C
h
ap
ter
7
7-4
Serial Communication Function
The followings are examples of messages (computer → inverter, inverter → computer (normal & abnormal response)).
1) Message from computer to inverter (RTU)
Item
Name
Description
①
IN
Inverter number
0: broadcast mode
1-247: termination inverter number
Data format is fixed as 1byte
Inverter number, the data set by function code F4006
Example: inverter number 2
①
→‗02‘
②
OP
Command code
Command code (1byte fixed)(03H, 06H, 10H)
③
DT
Data
Example
①
: Data content read from register(03H)
1
)
Register number (2-byte fixed)
Example: register number 07D0H
⑪
→‗07‘
⑫
→‗D0‘
2
)
Number of registers (2-byte fixed)
Example: two registers
⑬
→‗00‘
⑭
→‗02‘
·Data(DT)
(4byte)
(1)
(2)
(3)
(4)
Example
②
The contents of data when writing data in one register (06H)
1) Register number (2-byte fixed)
Example: register number 03E8H
⑪
→‗03‘
⑫
→‗E8‘
2)
Data content
(2-byte fixed)
Example: Setting register 0001H
(3)→‗00‘ (4)→‗01‘
·Data(DT) (4byte)
(1)
(2)
(3)
(4)
Example
③
Data content written into the register (10H)
1
)
Register number (2-byte fixed)
Example: register number 03E8H
⑪
→‗03‘
⑫
→‗E8‘
2
)
Setting of number of registers (2-byte fixed)
Example: setting register
⑬
→‗00‘
⑭
→‗01‘
3
)
Number of data (1-byte fixed)
Example: setting data
⑮
→‗02‘
4
)
Data content (variable, byte = number of data (5))
Example: Setting register 0001H
⑯
→‗00‘
⑰
→‗01‘
·Data(DT)
(7byte)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
④
SUM
Checksum