Table 6-7 Auto tuning mode
Function Code F1001
Function
Motor Parameters
Remarks
10
Auto tuning mode 1: Measure
when the motor shaft is fixed
Primary resistance R1
Secondary resistance R2
Primary inductance L1
Secondary inductance L2
Mutual inductance Lm
For cases where the motor
can not operate
11
Auto tuning mode 2: Measure
when the motor is operating
Primary resistance R1
Secondary resistance R2
Primary inductance L1
Secondary inductance L2
Mutual inductance Lm
Excitation current I0
Iron loss resistance Rm
Motor inertia Jm
For cases where the motor
can operate
Before setting the above auto tuning, set the following function codes in order.
Table 6-8 Auto tuning setting
Function Code
Content
Settings
Remarks
F5001
Motor poles, voltage and
capacity
XYZZZ
X: Polarity, Y : Rated voltage
Z: Motor capacity
F5002
Motor current rating
30 - 110% of the inverter
current rating (0.1A stepping)
F5003
Motor frequency rating
10 - 600 Hz
F5004
Motor speed rating
0 -
24000 rpm (1rpm stepping)
F5005
Motor insulation type
1: Type A
2: Type E
3: Type B
4: Type F
5: Type H
F5006
The motor‘s rated voltage
during auto tuning of motor
parameters
0: Use function code F5001
Selected voltage
100 -
460
(the voltage of F5001 is inactive)
F5007
Rated motor slip ratio
0-50%
*If motor parameters are known, please enter the parameters into the following function codes.
F5009 Motor stator resistance [Ω or m Ω]
F5010 Motor rotator resistance [Ω or m Ω]
F5011 Motor stator inductance [mH]
F5012 Motor rotator inductance [mH]
F5013 Motor mutual inductance [mH]
F5014 Motor excitation current [A]
F5015 Motor inertia moment [kgm
2
]
F5016 Load inertia moment ratio
Содержание SVCO6