- 132 -
7-3
Description of Functions
F1124
Deceleration exciting ratio
This function set exciting ratio during deceleration.
Code No.
Function Name
Data Content
Setting
Resolution
Factory
Presets
F1124
Deceleration exciting ratio
0.01-4
0.01
1
●
This function set over 1, excitation current of motor will be big during deceleration. The motor can decelerate
short time by regeneration power from load consumption in motor windings.
●
This function set less than 1, excitation current of motor will be small during deceleration.
Note 1: Exciting ratio set more big value, the inverter has possibility stop by over current protect.
Note 2: Exciting ratio set big value, the motor has possibility over heat, because the motor loss increases. Therefore
F1124 sets value that adaptive load and keeping motor cool level.