- 278 -
7-4
Serial Communication Function
2) Command c, d and e: The inverter cannot return a response to these batch control commands.
④
When sending commands c, d and e with no response from the inverter, the computer should insert an
interval of about 10 ms between two commands.
2
)
Message transmission and receive timings on the RS485 communication interface
When the RS485 communication interface is connected by 2-wire method, it will be half-duplex
communication line. Therefore, when transmitting and receiving a message, the computer should use the
timing described below when sending a collision between computer-sent and inverter-sent messages.
3
)
Specified command inverter‘s response selection
In order to improve communication speed, the response sent by inverter can be selected.
The communication formats of ASCII and BINARY will not return a response from an inverter to the
following commands. The error response can also be selected.
F4011=0: Sent
=1: Not sent (error response sent)
=2: Not sent (error response not sent)
①
ASCII-supported commands
N
,
O
,
P
,
Q
,
R
,
S
,
a
,
b
②
BINARY-supported commands
O
,
P
,
Q
,
R
⑱
List of character code
Upper 4 bits→
↓
M