- 88 -
7-2
Function Code List
– Input/Output-Related Function
Code
No.
Function Name
Data Content
Setting
Resolution
Factory
Presets
User
Setting
Value
1309
Operation direction switching in V/f
control mode
0: Start from the direction opposite to current
direction after a stop
1: Continuous operation
1
0
1315
Shortest operation time function
0 -99.99 sec.
0.01 s
0
1316
2nd Upper frequency limit
5-599 [Hz]
0.01 [Hz]
60
1317
3rd Upper frequency limit
5-599 [Hz]
0.01 [Hz]
60
1318
Cooling fan ON/OFF control
0: ON/OFF control
1: Normally ON
1
0
1319
Functions corresponding to high
altitude areas
1: 1,000m or below
2: 1,000m-1,500m or below
3: 1,500m-2,000m or below
4: 2,000m-2,500m or below
5:2,500m-3,000m
1
1
1320
Rating selection
1: Mode A (heavy overload mode) 150% 1 minute
2: Mode B (light overload mode) 120% 1 minute
1
1
Input/Output-Related Function
1401
Bias frequency (VIF1)
0-±600 [Hz]
(frequency at 0V or 4mA)
0.1 [Hz]
0
1402
Gain frequency (VIF1)
0-±600 [Hz]
(frequency at 5V or 10V or 20mA)
0.1 [Hz]
60
1403
Bias frequency (VIF2)
0-±600 [Hz]
(frequency at 0V or 4mA)
0.1 [Hz]
0
1404
Gain frequency (VIF2)
0-±600 [Hz]
(frequency at 5V or 10V or 20mA)
0.1 [Hz]
60
1405
Bias frequency (VIF3)
0-±600 [Hz]
(frequency at 0V or 4mA)
0.1 [Hz]
0
1406
Gain frequency (VIF3)
0-±600 [Hz]
(frequency at 5V or 10V or 20mA)
0.1 [Hz]
60
1407
External analog input filter time
constant (VIF1)
1-500(set value 1=10ms)
1
10
1408
External analog input filter time
constant (VIF2)
1-500(set value 1=10ms)
1
10
1409
External analog input filter time
constant (VIF3)
1-500(set value 1=10ms)
1
10
1410
Set frequency gain
0-100
1
0
1411
Analog input switching for set
frequency gain
0: No analog input
1: External analog VIF1 voltage (0
-
5V)
2: External analog VIF1 voltage
(0
-
10V or potentiometer)
3: External analog VIF2 voltage (0
-
5V)
4: External analog VIF2 voltage
(0
-
10V or potentiometer)
5: External analog VIF3 voltage (0
-
5V)
6: External analog VIF3 voltage
(0
-
10V or potentiometer)
7: External analog VIF1 current (4
-
20mA)
8: External analog VIF2 current (4
-
20mA)
9: External analog VIF3 current (4
-
20mA)
1
0
1412
MBS terminal input mode
1: Level triggered
2: Edge triggered
1
1
1413
ES input terminal function
1: NO external thermistor signal
2: NC external thermistor signal
1
1