- 158 -
7-3
Description of Functions
F1513
Relay 1 contact output selection
This function is used to select and output control circuit output terminals FA1, FB1, and FC1 relay contacts.
Code No.
Function Name
Data Content
Setting
Resolution
Factory
Presets
F1513
Relay 1 contact output
selection
0: Alarm
1: In operation 1
2: Undervoltage
3: End of simple scheduled operation
4: In operation 2
5: Frequency matching (1st speed frequency)
6: Frequency matching (1st to 16th speed frequencies)
7: Frequency arrival
8: Overload alarm level setting signal (the value of
F1704)
9: Electric thermistor pre-alarm signal
(80% of electric thermistor)
10: Radiator overheat pre-alarm signal
13
:
Excitation and DC braking signals
14
:
Lower frequency limit matching signal
15
:
Upper frequency limit matching signal
16: Servo on ready signal
17: Zero servo completion signal
18
:
FR signal
19
:
RR signal
20
:
2DF signal
21
:
3DF signal
22
:
5DF signal
23
:
9DF signal
24
:
AD2 signal
25
:
AD3 signal
26
:
JOG signal
27
:
MBS signal
28
:
ES signal
29
:
RST signal
31: Positioning completion signal
32: Discharge resistor on signal
36: Overload alarm level setting signal (Including when
in acceleration/deceleration )
42: Torque matching signal
43: Low speed detection signal
48: Forward run detection signal
49: Reverse run detection signal
59: Low torque order 60:Alarm
61: In FWD operation (Only 3wired operation)
62: In REV operation (Only 3wired operation)
1
0
See Table 7-3 (multifunctional output terminal) for action description of functions.