- 221 -
-
221
-
C
h
ap
ter
7
7-3
Description of Functions
F4007
Communication speed
The function to set communication speed.
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F4007
Communication speed
1: 1200bps
2: 2400bps
3: 4800bps
4: 9600bps
5: 19200bps
6: 38400bps
7: 57600bps
1
4
F4008
Parity bit
The function to set the parity bit.
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F4008
Parity bit
0: No
1: Odd
2: Even
1
1
F4009
Stop bit
The function to set the stop bit.
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F4009
Stop bit
1: 1 bit
2: 2 bits
1
1
F4010
End code
The function to set the end code for dedicated protocol communication function(SANKEN communication protocol).
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F4010
End code
0
:
CR+LF
1
:
CR
1
0