- 51 -
C
h
ap
ter
5
-
51
-
5-3 Status Display Mode
5-3-4
Command Setting
The command setting of the inverter frequency, speed and torque can be input by using the quick knob.
Command setting is possible by function code (F1201 and F1202) combination. Each command setting is difference
by 7-segment monitor state following bellow the table.
7-segment monitor state
F1201
F1202
Command setting
Frequency
1
*
Reference frequency
Output Current
2
*
Reference frequency
Speed of rotation
3
*
Disable command setting
Load factor
4
*
Reference frequency
Command speed in state display
5
7
Speed
Command frequency in state display
5
29
Reference frequency
Command torque in state display
5
30
Torque(Only vector control mode)
Speed of rotation in state display
5
52
Speed
State display(others)
5
others
Disable command setting
*Unrelated setting value
Command setting methods have two types.
(1)
Command setting A
Turn the quick knob, and press when the required command is obtained, thus the command is changed. This
is the method of command setting A.
This is an effective method for setting a desired command.
Cancellation can be made during command setting.
In status monitor display, the method of command setting A can be used either during in running or
stopping stopped state of the equipment.
This method can not be used during alarm display.
Operation example: changing the command frequency from 5 Hz to 50 Hz
Operation
Display
Description
or
Display of status monitor
(frequency display)
(press)
Press the quick knob, and the current set frequency will be
displayed
…
Turn the quick knob, and the value displayed will increase
or decrease.
…
Quickly turn the knob, and the displayed digit number of
increase
or decrease will be changed.
The frequency desired will be displayed.(*1)
or
(press)
or
Press the key or quick knob, then the set value will be
stored as a
new frequency value.
And the interface will
return to
status monitor display mode. If this is done during
running operation, then the output frequency will start to
change to the newly set value.
:Lit :Brightness periodically changes : Flashing
*1 If it is not necessary to set frequency, press key or key to return to the status monitor display mode.