- 240 -
7-3
Description of Functions
Note: When certain toque limit is selected (F6113=1), since there is no possible of overload in constant-power zone, the
certain torque output limit must be set (F6113=0).
Reference parameter
F5001 (motor poles, voltage and capacity)
F5004 (motor speed rating)
F6114
Speed limit selection
F6115
Speed limit value in torque control
(Forward run side)
F6116
Speed limit value in torque control
(Reverse run side)
The function to set speed limit value in torque control mode (speed sensor and speed sensorless).
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F6114
Speed limit selection
0: Speed limit under 1st speed frequency command
1: Speed limit in function codes
1
1
F6115
Speed limit value in torque control
(Forward run side)
0-8000rpm
1rpm
1800
F6116
Speed limit value in torque control
(Reverse run side)
0-8000rpm
1rpm
1800
● Carry out torque control within the speed range set by this function.
● When speed limit value is exceeded, switch the speed control using speed limit value as the command.
● When using F6114=0:1 speed frequency command to set the speed control, the synchronized speed operated from
1st speed frequency command will be used for speed control. In this case, the values should be set according to the
settings of 1st speed frequency setting selection (F1002).
Example) When the speed limit value is set within the scope of 0-5V with the external analog VIF3 input,
Speed limit selection: F6114=0.
1st speed frequency setting selection: F1002=6.
● When speed limit in function codes (F6114=1) is set, the speed limit value in torque control (forward run side)
(F6115) and speed limit value in torque control (reverse run side) (F6116) will be used for speed control. With the
default values, the setting of using function codes is effective. The speed limit values in forward run and reverse run
can be set separately. Also, when fixed speed limit value is required from the startup, please select the settings
described here.
Example When speed control value in forward run side is 1500rpm and the speed control value in reverse run side
is -1000rpm,
Speed limit selection: F6114=1.
Setting of speed control value: F6115=1500rpm, F6116=1000rpm.
Torque
Speed limit value in torque control
(forward run side)F6115=1500rpm
Torque command (positive)
Torque control
Speed control with speed limit value
Speed
Speed control
with speed limit value
Torque control
Torque command (negative)
Speed limit value in torque control
(reverse run side)F6116=1000rpm
Reverse
Forward