Description of Functions
This function is used to make the detection value of external analog signal stable and effective where interference exists
in the external analog signal. And, if the effective number of bits is reduced, then the action in S-shaped
acceleration/deceleration curve becomes more stable.
Effective number of bits for VIF1-3 detection
= 8, when this value is set, 4 lower bits are inactive.
= 9, when this value is set, 3 lower bits are inactive.
= 10, when this value is set, 2 lower bits are inactive.
= 11, when this value is set, 1 lower bit is inactive.
= 12, when this value is set, no inactive bit.
Effective number of bits can be assigned to VIF1, VIF2 and VIF3 independently.