Description of Functions
Operation signal
Forward
Reverse
Acceleration/deceleration
Forward/reverse
1 cycle
Time
9) Midway stop and midway start of simple
scheduled
operation
During simple
scheduled
operation, when the inverter must be stopped because of some undiscovered reason,
the deceleration time during this period can be set independently and separated from the operation timer.
When stop command between operation timers T1
-
T15 (including alarms) are entered into the inverter, the
inverter will stop deceleration or free run, and stay at the midway stop status during simple
scheduled
operation.
The stop deceleration time should be accorded to the deceleration time of midway stop deceleration time
(F2219). F2219 will make a choice from 1st deceleration time to 4th deceleration time of F1016
-
F1019.
F2219
Midway stop deceleration time
F2220
Midway start acceleration time
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F2219
Midway stop deceleration
time
1: 1st deceleration time (value of F1016)
2: 2nd deceleration time (value of F1017)
3: 3rd deceleration time (value of F1018)
4: 4th deceleration time (value of F1019)
1
1
F2220
Midway start acceleration
time
1: 1st acceleration time (value of F1012)
2: 2nd acceleration time (value of F1013)
3: 3rd acceleration time (value of F1014)
4: 4th acceleration time (value of F1015)
1
1
Note: When stop command (or
free run
) enters into the inverter, the current operation timer will be maintained, and prepared for
the next operation. When the operation command enters again, the operation timer will continue to work if original
frequency is reached.
· During midway stop, if the conditions for another start are satisfied, the inverter will start acceleration to the original
frequency set in the operation timer and enters into the midway start status. The acceleration time of this period is
accorded to the acceleration time of midway start acceleration time (F2220).
· F2220 can make a choice from 1st deceleration time to 4th deceleration time of F1012
-
F1015. When the pre-set
frequency is reached, the operation timer will work again.
Reference:
During midway stop, even if the power supply is cut off, it still can record the last status of
operation timer, therefore, when daily operation is finished and the inverter is stopped or the
power supply is cut off, the operation on the next day will continue with the last operation.
C
o
m
m
a
n
d
fr
equ
enc
y