- 282 -
7-4
Serial Communication Function
2) Message from inverter to computer (RTU) (normal response)
Item
Name
Description
①
IN
Inverter number
0: Broadcast mode
1-247: inverter number of sender
Data format is fixed as 1byte
Inverter number, the data set by function code F4006
Example: inverter number 2
①
→‗02‘
②
OP
Command code
same as the code sent from computer to inverter
③
DT
Data
Example
①
: Data content read from register(03H
)
1
)
Number of data (1-byte fixed)
Example: 4 data are read
⑪
→‗04‘
2
)
Data content (variable, byte = number of data (4))
Example: 4 data are read
⑫
→‗00‘
⑬
→‗00‘
⑭
→‗13‘
⑮
→‗88‘
·Data (DT)
(5byte)
(1)
(2)
(3)
(4)
(5)
Example
②
The contents of data when writing data in one register (06H)
1) Register number (2-byte fixed)
Example: register number 03E8H
⑪
→‗03‘
⑫
→‗E8‘
2)
Data content
(2-byte fixed)
Example: Setting register 0001H
(3)→‗00‘ (4)→‗01‘
·Data(DT)
(4byte)
(1)
(2)
(3)
(4)
Example
③
Data content written into the register (10H)
1
)
Register number (2-byte fixed)
Example: register number 07D1H
⑪
→‗07‘
⑫
→‗D1‘
2
)
Setting number of registers (2-byte fixed)
Example: writing in two registers
⑬
→‗00‘
⑭
→‗02‘
·Data (DT)
(4byte)
(1)
(2)
(3)
(4)
④
SUM
Checksum
CRC check (2-byte fixed)