Section 17 OS Timer (OSTM)
Caution 1.
Select a counter-clock-enable signal for OSTMn while the operation of OSTMn
is stopped (the OSTMnTE.OSTMnTE bit is 0).
Caution 2. After using the IC0CKSELn.IC0CKSELn[13:0] bits to select the counter-clock-
enable signal for OSTMn, set the IC0CKSELn.IC0TMENn bit to 1.
Caution 3. If TAUBn or TAUJn is selected as the source of a counter-clock-enable signal
for OSTMn (the IC0CKSELn.IC0TMENn bit is 1), do not change the operation
of TAUBn or TAUJn while the OSTMn is operating (the OSTMnTE.OSTMnTE
bit is 1).
[Setting procedure]
(1) Confirm that the OSTMnTE.OSTMnTE bit is 0 (OSTMn operation is
stopped).
(2) Set the IC0CKSELn.IC0CKSELn[13:0] bits to select a counter-clock-
enable signal for the OSTMn.
(3) Set the IC0CKSELn.IC0TMENn bit to 1.
(4) Enable OSTMn operation by setting the OSTMnTS.OSTMnTS bit to 1.