R01UH0336EJ0102 Rev.1.02
Page 1304 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 23 A/D Converter
• When A/D conversion on channel 2 is completed, the A/D conversion end
interrupt for CG0 (i.e. INTADCAnT0) is generated. If the circuit is operating
normally, the result of conversion will be 1/2 AV
DD
.
• When A/D conversion on channel 3 is completed, the A/D conversion end
interrupt for CG0 (i.e. INTADCAnT0) is generated. If the circuit is operating
normally, the result of conversion will be 2/3 AV
DD
.
When the diagnosis voltage of channel S/H circuit diagnostic is changed, set
ADCAnDGCTL0.ADCAnPSEL[2:0] bits to diagnosis voltage.
Idle
Conversion of CG1
Conversion of CG0
Status
CH7
CH1
CH2
CH3
Conversion
Sample
Conversion
Sample
Conversion
Sample
Conversion
Sample
DIAGOUT1
=1/3AV
DD
DIAGOUT2
=1/2AV
DD
DIAGOUT0
=2/3AV
DD
CG1
Start trigger
CG0
Start trigger
The setting of
the reference
voltage is changed
Hold
Hold
Hold
1/3AV
DD
2/3AV
DD
1/2AV
DD
A/D
conversion end
interrupt
INTADCAnT1
A/D
conversion end
interrupt
INTADCAnT0
A/D
conversion end
interrupt
INTADCAnT0
A/D
conversion end
interrupt
INTADCAnT0
1/3 AV
DD
is stored to the conversion result register
1/2 AV
DD
is stored to the conversion result register
2/3 AV
DD
is stored to the conversion result register