R01UH0336EJ0102 Rev.1.02
Page 630 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 14 Timer Array Unit J (TAUJ)
14.6.2
Simultaneous Start and Stop of Synchronous Channel
Counters
Channels that are operated synchronously can be started and stopped
simultaneously, both within a TAUJ unit and between TAUJ units.
(1)
Simultaneous start and stop within a TAUJ unit
• To simultaneously start synchronized channels, the TAUJnTS.TAUJnTSm
bits of the channels should be set at the same time.
• To simultaneously stop synchronized channels, the TAUJnTT.TAUJnTTm
bits of the channels should be set at the same time.
Setting 1 in the TAUJnTS.TAUJnTSm bits sets the corresponding
TAUJnTE.TAUJnTEm bits to 1, enabling counting. The count start timing of the
counter depends on the operating mode.
(2)
Simultaneous start between TAUJ units
Counters in different TAUJ units can also be started simultaneously if the
corresponding counters are enabled before receiving the simultaneous trigger
signal.
For details about how to make a simultaneous start between TAUJ units, see
Section 24.4.1, Simultaneous Start Trigger Function.
Содержание V850 Series