Section 13 Timer Array Unit B (TAUB)
(c)
Operation stop and restart
Figure 13-66
Operation Stop and Restart
Positive Logic (TAUBnTOL.TAUBnTOLm (Slave) = 0)
• The counter can be stopped by setting TAUBnTT.TAUBnTTm of master and
slave channels to 1. This sets TAUBnTE.TAUBnTEm to 0.
• TAUBnCNTm and TAUBnTTOUTm of all channels stop and the current
values are retained. No interrupts are generated.
• The counter can be restarted by setting TAUBnTS.TAUBnTSm of master
and slave channels to 1. TAUBnCNTm of master and slave channels reload
the current values of TAUBnCDRm and start to count down from these
values.
b
b
a + 1
a + 1
Master
b
Slave
Operation start
Operation start
Operation stop
TAUBnTS.TAUBnTSm
TAUBnTE.TAUBnTEm
TAUBnCNTm
TAUBnCDRm
INTTAUBnIm
TAUBnTS.TAUBnTSm
TAUBnTE.TAUBnTEm
TAUBnTTOUTm
TAUBnTTOUTm
TAUBnCNTm
TAUBnCDRm
INTTAUBnIm
0000
H
0000
H