R01UH0336EJ0102 Rev.1.02
Page 426 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
(3)
Synchronous channel output mode 2 with dead time output
In this output mode, a dead time delay is added to TAUBnTTOUTm. The set/
reset conditions are shown in the following figure.
Set/reset conditions
Figure 13-10
Set/Reset Conditions for Synchronous Channel Output Mode 2 with Dead
Time Output
With regard to the edge to which dead time is added, set
TAUBnTDL.TAUBnTDLm = 0 for rising edges and TAUBnTDL.TAUBnTDLm =
1 for falling edges.
Prerequisites
Dead time control requires a set of three channels, each operating in the
following modes:
• One master channel
The master channel should be set to interval timer mode.
• One even slave channel
The even slave channel should be set up/down count mode.
• One odd slave channel (even c 1)
The odd slave channel should be set to one-count mode.
The values of the following bits should be the same for the odd channel and
the even channel:
• TAUBnTOE.TAUBnTOEm
• TAUBnTOM.TAUBnTOMm
• TAUBnTOC.TAUBnTOCm
• TAUBnTDE.TAUBnTDEm
Duty
(INTTAUBnlm for
even slave channel)
Dead time
(INTTAUBnlm for
odd slave channel)
[When TAUBnTOL.TAUBnTOL = 0]
[When TAUBnTOL.TAUBnTOL = 1]
TAUBnTDL.TAUBnTDL = 0
TAUBnTDL.TAUBnTDL = 1
TAUBnTDL.TAUBnTDL = 1
TAUBnTDL.TAUBnTDL = 0