20.11.4
Receive/Transmit Operations in Each Operating Mode
The following table shows outline of the receive/transmit operations in each
operating mode.
Note 1. When the arbitration loss occurs, control of re-transmission is possible by
FCNnCMCLCTL.FCNnCMCLALBF.
Note 2. Signals to be generated are not output to outside, but remain in the FCN module.
Table 20-18
Outline of Receive/Transmit Operations in Each Operating Mode
Operating
Mode
Transmission
of Data/Remote
Frame
Transmission
of ACK
Transmission
of Error/
Overload
Frame
Transmission
Retry
Automatic
Block
Transmission
(ABT)
FCNnCMCLVALF
Setting
Store Data
to Message
Buffer
Initialization
mode
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Normal
operating
mode
Enabled
Enabled
Enabled
Enabled
Disabled
Enabled
Enabled
Normal
operating
mode with
ABT
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Receive-only
mode
Disabled
Disabled
Disabled
Disabled
Disabled
Enabled
Enabled
Single-shot
mode
Enabled
Enabled
Enabled
Disabled
*
1
Disabled
Enabled
Enabled
Self-test
mode
Enabled
*
2
Enabled
*
2
Enabled
*
2
Enabled
*
2
Disabled
Enabled
*
2
Enabled
*
2