V850E2/PG4-L
Section 20 CAN Controller (FCN)
Caution 1.
Do not set any transmission request while ABT transmission abort processing
is in progress.
Caution 2. Make a FCN sleep mode/FCN stop mode transition request after
FCNnGMABCTL.FCNnGMABABTT is cleared (after ABT mode is aborted)
following the procedure shown in Figure 20-26, ABT Transmission Request
Abort Processing (Normal Operating Mode with ABT) (1), or Figure 20-27, ABT
Transmission Request Abort Processing (Normal Operating Mode with ABT)
(2). When clearing a transmission request in an area other than the ABT area,
follow the procedure shown in Figure 20-24, Transmission Abort Processing
(Except Normal Operating Mode with ABT).
Note
There is the case that all ABT is transmitted completely even if transmission
abort interrupt is generated. Then, it is possible to know which message is
finished transmission.