R01UH0336EJ0102 Rev.1.02
Page 327 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 9 Safety Functions
(8)
SGAEPCTL - SGA Error Pulse Control Register
This register is used to select the timer for dynamic-mode operation (for
details, see Section 10.3.3, Operations for Error Output).
Access
This register can be read/written in 8-bit units.
Address
FF83 F020
H
Initial value
00
H
This register is initialized by a reset from any source.
(9)
BRAMDATn (n = 0 to 3) - Back-up RAM Register
The contents of on-chip RAM are undefined after self-diagnostic BIST. Since
this register may hold values before the execution of self-diagnostic BIST, save
the data beforehand. This 128-bit register is composed of four registers.
Access
This register can be read/written in 32-bit units.
Address
FF83 F030
H
(BRAMDAT0)
FF83 F034
H
(BRAMDAT1)
FF83 F038
H
(BRAMDAT2)
FF83 F03C
H
(BRAMDAT3)
Initial value
Undefined
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
SGATMSL
R
R
R
R
R
R
R
R/W
Table 9-17
Contents of the SGAEPCTL Register
Bit Position
Bit Name
Function
0
SGATMSL
This bit selects the source of the timer for input to the safety guardian.
0: TAUB0 channel15
1: OSTM1
127-96
95-64
63-32
31-0
BRAMDAT3
BRAMDAT2
BRAMDAT1
BRAMDAT0
R/W
R/W
R/W
R/W
Содержание V850 Series