R01UH0336EJ0102 Rev.1.02
Page 588 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
(e)Inhibited INTTAUBnIm to set TAUBnTTOUTm positive phase period
The following settings apply to the diagram below:
• Slave channel 2:
– Positive logic (TAUBnTOL.TOLm = 0 )
• Slave channel 3:
– Negative logic (TAUBnTOL.TOLm = 1)
Figure 13-89
TAUBnCDRm (master) = 0005
H
, TAUBnCDRm (slave 2) = 0005
H
,
TAUBnCDRm (slave 3) = 0001
H
PWM signal width (positive phase)
0
CDRm
(master) + 1
CDRm
(slave 2) load
CDRm
(slave 2) load
CDRm
(slave 3)
load
CDRm
(slave 3)
load
down up
Up/down switching
INT (slave 2) Reset
INT (slave 3) Set
Slave 3
Slave 2
Slave 3
Master
Slave 2
Slave 1
INT (slave 3)
INT (slave 2)
Concurrent occurrence =
Reset takes priority
No change
TAUBnCNTm
(master)
INTTAUBnIm
(master)
TAUBnTTOUTm
(master)
TAUBnCNTm
(slave 2)
INTTAUBnIm
(slave 2)
TAUBnCNTm
(slave 3)
INTTAUBnIm
(slave 3)
TAUBnTTOUTm
Slave 2 + 3
TAUBnTTOUTm
(slave 2)
[TAUBnTDL.
TAUBnTDLm = 0]
TAUBnTTOUTm
(slave 3)
[TAUBnTDL.
TAUBnTDLm = 1]
0001H
0000H
0000H