R01UH0336EJ0102 Rev.1.02
Page 1368 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 24 Peripheral Interconnection (PIC)
24.4.1.5
Operation Flow
Figure 24-2
Setting Flow
Note
For operation of the timers in simultaneous start function, refer to the section of
each timer.
24.4.1.6
Register Setting for Various Functions
Refer to Section 24.4.1.3, Registers.
START
Initial setting
Set register and operating mode for each timer
Timers
TAUB0m
TAUJ0
TSG20
TPBA0
OSTMn
ENC0
Start
Enable simultaneous start
(set PIC0SSER0, PIC0SSER2)
Set start trigger
(write 1 to the SYNCTRG bit)
Timers are simultaneously started
Simultaneous start
for other timers?
END
Yes
No