R01UH0336EJ0102 Rev.1.02
Page 510 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
(6)
Specific timing diagrams
(a)
Operation Stop and Restart
Figure 13-61
Operation Stop and Restart, TAUBnCMORm.TAUBnMD0 = 0,
TAUBnCMURm.TAUBnTIS[1:0] = 00
B
• The counter can be stopped by setting TAUBnTT.TAUBnTTm to 1, which in
turn sets TAUBnTE.TAUBnTEm to 0.
• TAUBnCNTm stops and the current value is retained.
• If the counter is stopped, valid TAUBnTTINm input edges are ignored.
• The counter can be restarted by setting TAUBnTS.TAUBnTSm to 1.
TAUBnCNTm restarts to count from 0000
H
.
Operation starts
Operation starts
Operation stops
0000
H
FFFF
H
TAUBnTS.TAUBnTSm
TAUBnTT.TAUBnTTm
TAUBnTE.TAUBnTEm
TAUBnTTINm
TAUBnCNTm
TAUBnCDRm
INTTAUBnIm